Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pers Med ; 13(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37763052

RESUMO

Total hip arthroplasty (THA) is commonly performed using off-the-shelf implants. In the case of a severe mismatch between the anatomy of the proximal femur and the geometry of the stem, the use of custom-made stems might become necessary. The goal of this study was to investigate the precision of the implantation of custom-made stems of one manufacturer (CTX stem, AQ Implants) and to determine risk factors for malpositioning. All patients receiving a custom-made CTX stem between 2014 and 2020 at six high-volume academic centers were retrospectively recruited. The achieved position of the stem, as determined by stem version, stem coronal angle, and implantation depth on radiographs, was compared to the plan. The influence of radiographic and demographic parameters on the position was investigated. The results revealed a high variability of the achieved implant position in relation to the preoperative plan. While the stem coronal angle only differed slightly from the intended position, the stem version and the implantation depth showed a high frequency and amount of deviation. Right stems showed significantly higher positions than planned. Surgeons must be aware of this potential problem when implanting custom-made stems.

2.
In Vivo ; 36(2): 672-677, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35241521

RESUMO

BACKGROUND/AIM: Increasing economic pressure in modern healthcare necessitates an increase in efficiency in total knee arthroplasty (TKA) while maintaining high-quality outcomes. Removal of debris using pulsatile lavage (PL) during cement polymerization may considerably reduce the operative duration. However, water can penetrate the interface, resulting in impaired implant fixation. The aim of the present study was to investigate the impact of early-onset PL during bone cement polymerization on implant fixation and operative duration. MATERIALS AND METHODS: Cemented implantation of tibial trays was performed in 20 fresh-frozen human tibiae from 10 donors in a matched-pair study design in two groups: 1) PL during cement polymerization; and 2) PL after completion of the polymerization process. The cement penetration depth was analysed by computed tomography (CT), and the pull-out force was measured to evaluate primary implant fixation. The duration of the procedure was recorded for both groups. RESULTS: Comparable pull-out forces were observed in the experimental (2,213 N) and control groups (2,350 N; p=0.68). The mean depth of cement penetration was similar in both groups. PL during cement polymerization could decrease the operative duration by 10 min. CONCLUSION: The application of PL during cement polymerization could significantly reduce operative duration and had no adverse effect on the mechanical fixation of the tibial component.


Assuntos
Artroplastia do Joelho , Artroplastia do Joelho/efeitos adversos , Cimentos Ósseos , Cadáver , Cimentação/métodos , Humanos , Irrigação Terapêutica/métodos , Tíbia/cirurgia
3.
Knee Surg Sports Traumatol Arthrosc ; 29(8): 2379-2385, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33710414

RESUMO

PURPOSE: Health care systems in most European countries were temporarily restructured to provide as much capacity as possible for the treatment of coronavirus disease 2019 (COVID-19) patients. Subsequently, all elective surgeries had to be cancelled and postponed for months. The aim of the present study was to assess the pretreatment health status before and after COVID-19-related cancellation and the psychosocial distress caused by the cancellation. METHODS: For this study, a questionnaire was developed collecting sociodemographic data and information on health status before and after the cancellation. To assess psychosocial distress, the validated depression module of the Patient Health Questionnaire (PHQ-9), was implemented. PHQ-9-Scores of 10 and above were considered to indicate moderate or severe depressive symptoms. In total, 119 patients whose elective orthopaedic surgery was postponed due to the COVID-19 pandemic were surveyed once at least 8 weeks after the cancellation. RESULTS: Seventy-seven patients (65%; 34 female, 43 male) completed the questionnaire and were included. The predominant procedures were total knee arthroplasty (TKA), hip arthroscopy and foot and ankle surgery. The mean pain level significantly increased from 5.5 ± 2.2 at the time of the initially scheduled surgery to 6.2 ± 2.5 at the time of the survey (p < 0.0001). The pain level before cancellation of the surgery was significantly higher in female patients (p = 0.029). An increased analgetic consumption was identified in 46% of all patients. A mean PHQ-9 score of 6.1 ± 4.9 was found after cancellation. PHQ-9 scores of 10 or above were found in 14% of patients, and 8% exhibited scores of 15 points or above. Significantly higher PHQ-9 scores were seen in female patients (p = 0.046). No significant differences in PHQ-9 scores were found among age groups, procedures or reasons for cancellation. CONCLUSION: Cancellation of elective orthopaedic surgery resulted in pain levels that were significantly higher than when the surgery was scheduled, leading to increased analgesic use. Additionally, significant psychosocial distress due to the cancellation was identified in some patients, particularly middle-aged women. Despite these results, confidence in the national health care system and in the treating orthopaedic surgeons was not affected. LEVEL OF EVIDENCE: Level III.


Assuntos
COVID-19 , Procedimentos Ortopédicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor , Pandemias , SARS-CoV-2
4.
Stud Health Technol Inform ; 270: 1415-1416, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32570686

RESUMO

openEHR and FHIR are two competing clinical data modeling and data exchange standards, that are commonly seen as mostly incompatible. However, the two have quite much in common and bridging approaches between the two worlds can serve the benefit of both communities. In the presented work, the data models of openEHR are translated into FHIR data models.


Assuntos
Registros Eletrônicos de Saúde
5.
Stud Health Technol Inform ; 243: 80-84, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28883175

RESUMO

Extraction of structured data from textual reports is an important subtask for building medical data warehouses for research and care. Many medical and most radiology reports are written in a telegraphic style with a concatenation of noun phrases describing the presence or absence of findings. Therefore a lexico-syntactical approach is promising, where key terms and their relations are recognized and mapped on a predefined standard terminology (ontology). We propose a two-phase algorithm for terminology matching: In the first pass, a local terminology for recognition is derived as close as possible to the terms used in the radiology reports. In the second pass, the local terminology is mapped to a standard terminology. In this paper, we report on an algorithm for the first step of semi-automatic generation of the local terminology and evaluate the algorithm with radiology reports of chest X-ray examinations from Würzburg university hospital. With an effort of about 20 hours work of a radiologist as domain expert and 10 hours for meetings, a local terminology with about 250 attributes and various value patterns was built. In an evaluation with 100 randomly chosen reports it achieved an F1-Score of about 95% for information extraction.


Assuntos
Armazenamento e Recuperação da Informação , Radiografia Torácica , Sistemas de Informação em Radiologia , Algoritmos , Humanos , Radiologia , Terminologia como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...